                     Description
Europe is the new GNR Benchtop Theta/2Theta powder diffraction system for XRD qualitative and quantitative analysis of polycrystalline materials.
With an achievable FWHM peak resolution < 0.04° 2Θ and an angular accuracy < ± 0.015° over the whole 2theta angular range, Europe guarantees the necessary level of performance for the most demanding x-ray diffraction
material investigation in a compact and low cost configuration.
Europe is capable to perform these measurements:
- Qualitative and Quantitative Crystalline Phase Analysis 
 - Degree of Crystallinity Calculation 
 - Polymorph Screening 
 - Cell parameters, Crystallite size and Lattice strain determination 
 - Rietveld refnement for structural characterization 
 - Retained Austenite Quantifcation
 
Features
- Compact Size: its compact size and robust design enable installation in a lab bench and operations in a small space.
 - Theta/2Theta Goniometer: GNR develops an ultra-compact goniometer that, adopting stepper motors with optical encoders, ensure extremely precise angular positioning. The double axis goniometer provides two indipendent angular degrees of freedom with common centre of rotation.
 - Optics: X-Ray beam collimation is obtained by variable slits that guarantee a perfect alignment of the beam in the equatorial direction, while in the axial direction the divergence is limited by soller slits. Europe can mount glass and ceramic X-Ray tubes with high reproducibility and stability of focus position.
 - X-Ray Detectors: Nal(TI) Scintillation Counter / Fast Detector
 - Sample holders: several sample holders are available to meet the specific needs of each laboratory (Rotating Sample Stage, Standard and Custom Sample Holders, Air Sensitive Sample Holder, 6 Position Automatic Sample Changer).
 
Application
- Geology and Mineralogy / Clays 
 - Glass / Ceramics / Cement  
 - Chemicals / Petrochemicals  
 - Catalyst / Polymers 
 - Forensics 
 - Agricultural Sciences  
 - Biosciences / Environmental 
 - Pharmaceuticals  
 - Cosmetics  
 - Art and Archeology 
 
| [Goniometer]: | Geometry Theta / 2Theta; Type Vertical; Radius; 150 mm; Scanning Range - 5° to + 145° (Theta/ 2Theta); Accuracy ± 0.01°; Minimum step angle 0.005°; | 
| [Generator]: | Maximum Power 600 W; Generation 40 kV / 15 mA; Tube Cr / Co / Cu - Glass or Ceramic Tube | 
| [Detectors]: | Scintillation Counter Nal (TI); Fast Detector (DECTRIS Mythen Multi Strip Detector) | 
| [Optics]: | Divergence Slit Variable 0-4°; Scattering Slit Variable 0-4°; Receiving Slit Variable 0-6 mm; Soller Slit Fixed 2.3° | 
| [Accessories]: | Secondary Graphite Monochromator (HOPG); Ks Filter; Aluminum / Plexiglas Sample Holder; Zero Background; Spinner; Multiple Sample Holder (6 / 20 mm diameter); Air Sensitive Sample Holder | 
| [Cooling Water]: | External Compact Low Noise Version - 377 W x 615 H x 435 D (mm) / 32 kg | 
| [Dimension]: | 700 W x 760 H x 460 D (mm) | 
| [Weight]: | 95Kg | 
| [Computer]: | External Desktop PC with Windows 8 | 
      