NDrop100 Microvolume NanoDrop
3 models, supports cuvette & fluorescence
Microvolume UV-Vis Spectrophotometer: A Powerful Tool for Precise Analysis
The 100C Microvolume UV-Vis Spectrophotometer is a cutting-edge analytical instrument designed for accurate and efficient quantification of nucleic acids, proteins, and cell cultures. This compact and portable device combines the versatility of full-wavelength spectrophotometry with the precision of microvolume measurement, making it an indispensable tool for a wide range of scientific and industrial applications.
Key Features
Micro and Cuvette Detection Modes: The ND-100C offers unparalleled flexibility, allowing for both microvolume and conventional cuvette-based measurements. This versatility enables precise analysis of a variety of sample types, including nucleic acid arrays, pure proteins, labeled proteins, and microbial cell cultures.
Rapid and Reliable Results: With a power-on self-test function and no warm-up time required, the ND-100C delivers quick and accurate results. The instrument's ability to perform measurements in approximately 5 seconds per sample significantly enhances workflow efficiency.
Ultra-Low Sample Volume: Requiring as little as 0.5 microliters of sample per test, the ND-100C conserves precious resources and minimizes sample wastage.
Portability and Upgradability: The compact design of the ND-100C makes it ideal for field use, while the USB upgradeable software ensures that the instrument stays up-to-date with the latest advancements.
Wide Concentration Range: The spectrophotometer's broad detection range eliminates the need for sample dilution in most cases, saving time and effort.
Colony Detection: The ND-100C supports colony detection in both micro and cuvette modes, providing comprehensive analysis capabilities.
Kinetic Measurements: When used with cuvettes, the instrument can perform kinetic studies, enabling the monitoring of reaction rates and processes.
Applications
The ND-100C Microvolume UV-Vis Spectrophotometer finds extensive applications across various fields, including:
Life Sciences: Nucleic acid and protein quantification, enzyme kinetics, cell growth monitoring, and microbial analysis.
Biotechnology: Quality control, drug discovery, and development.
Environmental Science: Water quality testing, pollutant analysis, and environmental monitoring.
Food and Beverage Industry: Quality control, contaminant detection, and nutritional analysis.
Clinical Diagnostics: Biochemical analysis and disease markers.
Conclusion
The ND-100C Microvolume UV-Vis Spectrophotometer is a powerful and versatile instrument that delivers exceptional performance, ease of use, and portability. Its ability to handle both micro and cuvette-based measurements, combined with its rapid analysis capabilities, makes it an invaluable asset for researchers, scientists, and quality control professionals alike.
Order Information
NDrop100 Microvolume Spectrophotometer
NDrop100C Microvolume / Cuvette Dual Mode Spectrophotometer
NDrop100F Microvolume / Cuvette / FluorescenceTri-mode Spectrophotometer
NDrop100 Microvolume Spectrophotometer | |
---|---|
[Minimum Sample Volume]: | 0.5 - 2 μL |
[Concentration Detection Range]: | 2 - 15000 ppm (ng/μL, dsDNA) |
[Measurement Time]: | 5 seconds (with wide concentration range detection) |
[Path Length]: | ≤ 0.7mm |
[Absorbance Range]: | 0.04 - 300 Abs (cuvette measurement) |
[Absorbance Accuracy]: | 1% (0.76 Abs@256nm) |
[Wavelength Range]: | 200-850nm |
[Wavelength Accuracy]: | < 1nm |
[Wavelength Resolution]: | ≤2nm |
[Light Source]: | Xenon lamp |
[Detector]: | CCD |
[Microvolume Platform]: | 304 stainless steel, quartz fiber |
[Sample Storage]: | 1000 data entries, exportable to USB flash drive |
[Power Supply]: | 12V 5A, 20W |
[Machine Dimensions]: | W197mm, D327mm, H181mm |
[Machine Weight]: | 3.1 kg |
NDrop100C Microvolume / Cuvette Dual-Mode Spectrophotometer | |
---|---|
[Minimum Sample Volume]: | 0.5 - 2 μL (Microvolume) |
[Concentration Detection Range]: | 2 - 15000 ppm (ng/μL, dsDNA) |
[Measurement Time]: | 5 seconds (with wide concentration range detection) |
[Cuvette Size]: | 12.5mm x 12.5mm standard cuvette |
[Cuvette Path Length]: | 10mm, 5mm, 2mm, 1mm adjustable |
[Cuvette Light Spot Height]: | 6mm |
[Cuvette Temperature Control]: | 37°C (±0.5°C) |
[Cuvette Stirring Speed]: | 130 - 900 rpm |
[Cuvette Concentration Detection Range]: | 0.2 - 750 ppm (ng/μL, dsDNA) |
[Cuvette Absorbance Range]: | 0.004 - 25 Abs (10mm path length condition) |
[Path Length]: | ≤ 0.7mm |
[Absorbance Range]: | 0.04 - 300 Abs (cuvette measurement) |
[Absorbance Accuracy]: | 1% (0.76 Abs@256nm) |
[Wavelength Range]: | 200-850nm |
[Wavelength Accuracy]: | < 1nm |
[Wavelength Resolution]: | ≤2nm |
[Light Source]: | Xenon lamp |
[Detector]: | CCD |
[Microvolume Platform]: | 304 stainless steel, quartz fiber |
[Sample Storage]: | 1000 data entries, exportable to USB flash drive |
[Power Supply]: | 12V 5A, 20W |
[Machine Dimensions]: | W197mm, D327mm, H181mm |
[Machine Weight]: | 3.1 kg |
NDrop100F Microvolume / Cuvette / Fluorescence Triple-Mode Spectrophotometer | |
---|---|
[Minimum Sample Volume]: | 0.5 - 2 μL (Microvolume) |
[Concentration Detection Range]: | 2 - 15000 ppm (ng/μL, dsDNA) |
[Measurement Time]: | 5 seconds (with wide concentration range detection) |
[Cuvette Size]: | 12.5mm x 12.5mm standard cuvette |
[Cuvette Path Length]: | 10mm, 5mm, 2mm, 1mm adjustable |
[Cuvette Light Spot Height]: | 6mm from the bottom |
[Cuvette Temperature Control]: | 37°C (±0.5°C) |
[Cuvette Stirring Speed]: | 130 - 900 rpm |
[Cuvette Concentration Detection Range]: | 0.2 - 750 ppm (ng/μL, dsDNA) |
[Cuvette Absorbance Range]: | 0.004 - 25 Abs (10mm path length condition) |
[Fluorescence Detection Sample Volume]: | 1 – 20 μL |
[Fluorescence Measurement Time]: | approximately 3s |
[Fluorescence Excitation Channel]: | Blue light 430nm-495nm |
[Fluorescence Emission Channel]: | Green light 510nm – 580nm |
[Fluorescence Dynamic Range]: | 5 orders of magnitude |
[Path Length]: | ≤ 0.7mm |
[Absorbance Range]: | 0.04 - 300 Abs (cuvette measurement) |
[Absorbance Accuracy]: | 1% (0.76 Abs@256nm) |
[Wavelength Range]: | 200-850nm |
[Wavelength Accuracy]: | < 1nm |
[Wavelength Resolution]: | ≤2nm |
[Light Source]: | Xenon lamp |
[Detector]: | CCD |
[Microvolume Platform]: | 304 stainless steel, quartz fiber |
[Sample Storage]: | 1000 data entries, exportable to USB flash drive |
[Power Supply]: | 12V 5A, 20W |
[Machine Dimensions]: | W197mm, D327mm, H181mm |
[Machine Weight]: | 3.1 kg |