Introduction
Compact FTIR for operation with ATR fibered probes
The Arcoptix FTIR-FC (Fiber-Coupling) is a variant of our FTIR Rocket spectrometer especially designed for operation with mid-IR optical fiber probes. It is a plug-and-play instrument including an IR source, high-stability interferometer, IR detector and SMA fiber couplers. The instrument was especially developed with process-monitoring applications in mind, using fibered ATR probes. For a selection of ATR probes, pelase open the "Accessories" tab.
Fibered ATR Probe for Infrared Spectrum
4-TE or Liquid-Nitrogen cooled MCT detectors available
The Arcoptix FTIR-FC can be equipped with both 4-stage thermo-electrically (TE) cooled or liquid-nitrogen cooled MCT detectors. The TE-cooled detectors in the FTIR-FC are the most sensitive TE-cooled detectors availabe on the market and offer a reliable and maintenance-free operation. For ultimate sensitivity levels, the FTIR-FC can also be equipped with a liquid-nitrogen cooled detector. The 4-TE and liquid-nitrogen cooled detectors are intercheangable by the user.
ATR probe in the liquid cell
Features
- Ideal for operation with fibered ATR probes
- All-in-one solution: source, interferometer, detector and fiber-couplers
- Most compact fiber-coupled FT-IR on the market
- Available with TE-cooled or liquid-nitrogen cooled MCT detectors
Fibered ATR Probe
- Chemically inert diamond-brazing technology
- Excellent throughput from 3µm to 18µm
- Temperature stability from -100°C to 170°C
- Pressure stability up to 300 bars
Applications
Chemical process-control with fibered ATR probes
The Arcoptix FTIR-FC was developed with chemical process-control applications in mind, using ATR fibered probes. These probes can be immersed into highly corrosive liquids at high temperatures and pressures, making them suitable for use in chemical reaction vessels and other extremely harsh environments. A list of available probes can be found under the Accessories tab.
Order Information
FTIR-FC-4TE 4-stage thermo-electrically (TE) cooled MCT detector
FTIR-FC-LN liquid-nitrogen cooled MCT detector
Crystal material | Diamond | Diamond | Diamond | Diamond | Silicon |
Shaft diameter [mm] | 3,17 | 6 | 6 | 12 | 6 |
Fiber Type | AgHal-Broad | AgHal-Narrow | AgHal-Broad | AgHal-Broad | AgHal-Broad |
Transmission Range [μm] | 3 to 17 | 5.2 to 17 | 3 to 17 | 3 to 17 | 3 to 17 |
Temperature Range [°C] | -150 to 140 | -50 to 135 | -150 … 170 | -150 … 275 | -150 … 140 |
Pressure Range, up to [bar] | 200 | 30 | 200 | 300 | 100 |
Shaft material | Hastelloy C22 | Stainless steel (type 1.4541) | Hastelloy C22 | Hastelloy C22 | Hastelloy C22 |
Probe length [m] | 1.5 | 1.5 | 1.7 | 1.7 | 1.7 |
Shaft length [mm] | 150 | 150 | 280 | 280 | 280 |
Protective tubing | Liquid Tight Stainless Steel | Liquid Tight Stainless Steel | Liquid Tight Stainless Steel | Liquid Tight Stainless Steel | Liquid Tight Stainless Steel |
Connector type | SMA | SMA | SMA | SMA | SMA |
[FTIR-FC-4TE 4-stage thermo-electrically (TE) cooled MCT] | |
---|---|
Spectral Range [1/cm]: | 5000-800 |
Spectral Range [μm]: | 2 - 12 |
Detector Type: | MCT, 4-TE cooled |
Detector D* [cm Hz1/2W-1]: | >2.5E9 |
Interferometer type: | Permanently aligned, double retro-reflector design |
Beam-splitter material: | ZnSe |
Resolution (unapodized) [cm-1]: | 4 |
Wavenumber repeatability: | <10PPM |
Scan frequency: | 1 spectrum / second |
Reference laser: | Temperature-stabilized solid-state laser @850nm |
Integrated light source: | 20W SiC globar with electronic stabilization |
Operating temperature: | 5°C-40°C |
Fiber optic interfaces: | SMA 905 connectors, fiber core up to Ø 1mm, NA=0.3 |
2 connectors for 4mm OD tubes: | 2 connectors for 4mm OD tubes |
Power requirement: | 12V / 30W |
Communication Interface: | USB 2.0 |
Software Interface: | Windows 7/8/10 API for controlling the instrument via our DLL |
Weight: | 2.2Kg |
[FTIR-FC-LN liquid-nitrogen cooled MCT] | |
---|---|
Spectral Range [1/cm]: | 5000-625 |
Spectral Range [μm]: | 2 - 16 |
Detector Type: | MCT, liquid nitrogen cooled |
Detector D* [cm Hz1/2W-1]: | >3E10 |
Interferometer type: | Permanently aligned, double retro-reflector design |
Beam-splitter material: | ZnSe |
Resolution (unapodized) [cm-1]: | 4 |
Wavenumber repeatability: | <10PPM |
Scan frequency: | 1 spectrum / second |
Reference laser: | Temperature-stabilized solid-state laser @850nm |
Integrated light source: | 20W SiC globar with electronic stabilization |
Operating temperature: | 5°C-40°C |
Fiber optic interfaces: | SMA 905 connectors, fiber core up to Ø 1mm, NA=0.3 |
2 connectors for 4mm OD tubes: | 2 connectors for 4mm OD tubes |
Power requirement: | 12V / 30W |
Communication Interface: | USB 2.0 |
Software Interface: | Windows 7/8/10 API for controlling the instrument via our DLL |
Weight: | 2.2Kg |