Labsys evo Thermogravimetry

Labsys evo Thermogravimetry

Stock Status: In Stock


Introduction

Simplicity of use: thanks to both an ergonomic design and the dedicated market leading Calisto software, LABSYS evo is user friendly and intuitive to operate - Wide temperature range: TGA with simultaneous DTA or DSC and Cp measurement can be achieved for temperature up to 1600 °C - High Precision Cp Measurement: the unique 3D (Calvet type) multiple thermocouples design enables large mass to be measured and to perform a Cp within 2 % , throughout the whole temperature range (ambient – 1 600 °C) - New top loading balance: the unmatched stability, reproducibility and accuracy of this new balance offer unparalleled TGA dataNEW! LABSYS evo TGA, TGA-DSC, TGA-DTA is available with an Auto Sampler (30 samples and 6 references)

Features

  • EVOLVED GAS ANALYSIS
    LABSYS evo offers a “Plug & play” gas analyzer coupling device,enabling simultaneous MS and FTIR connections. The coupling device is heated up to 300 °C to avoid any gas condensation and is complete ly insulated for a safe handling.
  • AUTO SAMPLER
    A NEW auto sampler system is available for Labsys evo TGA, TGA-DSC, TGA-DTA providing 30 samples and 6 references possibilities.

Applications

With its wide temperature range (ambient to 1600 °C ) LABSYS evo has a wide range of applications for DSC/DTA, TGA, simultaneous TGA-DSC/DTA, Cp measurements. Various fields of application are possible including polymers and plastics, advanced materials, pharmaceutical compounds, inorganic substances, thermodynamics (Specific Heat Capacity Cp precision within 2 %), energy, etc.
View the application notes in your field, available for download, by visiting our Application Library area. We have also included a
powerful search engine that will enable you to find the most applicable data.

Order Information

Labsys evo Thermogravimetry TGA

Optional Accessories

Gas mass flow controller 
30 samples, six reference autosampler 
Evolved Gas Analyzer (TGA Coupled)


Specifications
[Temperature range]: RT~1600℃ or RT~1150℃
[Scanning rate]: 0.01~100 K/min
[Maximum balance capacity]: 20g
[Weight range]: +/-1000 mg;+/-200 mg
[TG resolution]: 0.2μg;0.02μg
[Autosampler]: 30 samples and 6 references 4-prong gripper
[Vacuum]: 10^-1 mbar
[Gases]: Two inlets for gas scanning (inert or reactive) OR 3 carrier gases (option) (MFC from 4 to 200 ml/min) + 1 auxiliary or reactive gas (MFC from 0.3 to 16 ml/min)
[Evolved gas]: simultaneous MS, FTIR, GC, GC/MS couplings
We rely on cookies to provide our services. By using our services, you agree to our use of cookies.